RFC3571 - Framework Policy Information Base for Usage Feedback
Network Working Group D. Rawlins
Request for Comments: 3571 MCI
Category: Informational A. Kulkarni
Intel
K. Chan
Nortel Networks
M. Bokaemper
Juniper Networks
D. Dutt
Cisco
August 2003
Framework Policy Information Base for Usage Feedback
Status of this Memo
This memo provides information for the Internet community. It does
not specify an Internet standard of any kind. Distribution of this
memo is unlimited.
Copyright Notice
Copyright (C) The Internet Society (2003). All Rights Reserved.
Abstract
This document describes a portion of the Policy Information Base
(PIB) to control policy usage collection and reporting in a device.
The provisioning classes specified here allow a Policy Decision Point
(PDP) to select which policy objects should collect usage
information, what information should be collected and when it should
be reported.
This PIB requires the presence of other PIBs (defined elsewhere) that
provide the policy objects from which usage information is collected.
Table of Contents
1. IntrodUCtion . . . . . . . . . . . . . . . . . . . . . . . . . 2
2. General Concepts . . . . . . . . . . . . . . . . . . . . . . . 3
2.1. Selection, Usage and Linkage Policies. . . . . . . . . . 3
2.2. Normal Operations. . . . . . . . . . . . . . . . . . . . 4
2.2.1. Connection Establishment and Initial
Configuration Request. . . . . . . . . . . . . . 4
2.2.2. Unsolicited Reports - Periodic Reporting . . . . 5
2.2.3. Unsolicited Reports - Reporting Conditions . . . 5
2.2.4. Solicited Reports. . . . . . . . . . . . . . . . 6
2.2.5. Resuming and Suspending Periodic Feedback
Reporting. . . . . . . . . . . . . . . . . . . . 6
2.2.6. Failover . . . . . . . . . . . . . . . . . . . . 6
2.3. Usage Policy and Under-specified Selection Criteria. . . 7
3. Summary of the Feedback Framework Policy Information Base. . . 8
3.1. SPPI Access Clause Report-Only . . . . . . . . . . . . . 8
3.2. Usage32 and Usage64 Textual Conventions. . . . . . . . . 8
3.3. Feedback Groups and PRCs . . . . . . . . . . . . . . . . 9
3.3.1. Feedback Action. . . . . . . . . . . . . . . . . 9
3.3.2. Feedback Action List . . . . . . . . . . . . . . 10
3.3.3. Feedback Linkage Capability. . . . . . . . . . . 10
3.3.4. Feedback Linkage . . . . . . . . . . . . . . . . 10
3.3.5. Feedback Traffic Statistics Threshold. . . . . . 10
3.3.6. Feedback Traffic . . . . . . . . . . . . . . . . 10
3.3.7. Feedback Interface Traffic . . . . . . . . . . . 11
3.3.8. Feedback RoleCombo Filter Selection. . . . . . . 11
4. The Feedback Framework PIB Module. . . . . . . . . . . . . . . 11
5. Security Considerations. . . . . . . . . . . . . . . . . . . . 31
6. IANA Considerations. . . . . . . . . . . . . . . . . . . . . . 32
7. Acknowledgements . . . . . . . . . . . . . . . . . . . . . . . 32
8. References . . . . . . . . . . . . . . . . . . . . . . . . . . 32
8.1. Normative References . . . . . . . . . . . . . . . . . . 32
8.2. Informational References . . . . . . . . . . . . . . . . 33
9. Authors' Addresses . . . . . . . . . . . . . . . . . . . . . . 34
10. Full Copyright Statement . . . . . . . . . . . . . . . . . . . 35
1. Introduction
The Framework of Common Open Policy Service with Policy Provisioning
(COPS-PR) Usage Feedback describes the overall approach to policy
usage monitoring and reporting. This document defines the specific
Policy Information Base (PIB) framework for policy usage feedback.
The policy classes for monitoring and reporting policy usage
feedback, as well as policy classes for controlling reporting
intervals, suspension, resumption and solicitation are defined.
Conventions Used in this Document
The key Words "MUST", "MUST NOT", "REQUIRED", "SHALL", "SHALL NOT",
"SHOULD", "SHOULD NOT", "RECOMMENDED", "MAY" and "OPTIONAL" in this
document are to be interpreted as described in [RFC2119].
2. General Concepts
2.1. Selection, Usage and Linkage Policies
There are three basic types of policies used to define what the PEP
is to monitor, record and report. These are the selection criteria
policy, the usage policy and the feedback report linkage policy.
The selection criteria policy is installed by the PDP. It defines
the conditions used by the PEP to monitor and record a usage policy.
The selection criteria policy may only be used for defining usage
feedback selection criteria. However, a more general case is a
policy that already exists for policy enforcement that may also be
used for specifying feedback usage selection criteria. An example of
this is the frwkRoleCombo instance, which may be used in defining QoS
enforcement policies, but may also be used to specify conditions on
which to base usage - i.e. count the number of packets meeting the
criterion of an interface capability set name and role combination.
The usage policy defines what attributes are recorded by the PEP.
These policies have an ACCESS clause of 'report-only'. Generally,
the usage policies specify counts related to a specific action such
as a packet being dropped. The feedback framework PIB defines two
usage policy classes, frwkFeedbackTraffic and frwkFeedbackIfTraffic.
Usage PRCs may be generic, collecting basic statistics, or they may
be specific to a particular usage. The PDP decides which PRC(s) best
suit(s) its requirements. The PEP may support only one usage
feedback PRC, in which case all statistics are gathered using
instances of that PRC. Alternatively, the PEP may support multiple
usage feedback PRCs. The PDP then decides which PRC to associate
with a particular selection criterion.
A usage feedback policy and selection policy are tightly associated
with one another. A third policy, the frwkFeedbackLinkTable, is used
to associate, or provide a linkage for the selection and usage
policies. The frwkFeedbackLinkTable also specifies when to report
the usage feedback. The frwkFeedbackLinkTable entry permits the same
selection criteria instance to be re-used for various usage feedback
policies. The frwkFeedbackLinkTable contains the value of the
selection criteria instance as well as the value of the usage
feedback PRC.
----------------- ------------------ -----------------
Select Criteria Linkage Instance Usage Instance
-instance ID - instance ID
-instance ID <---PRID of selection--->- PRID of Linkage
-conditions... -PRC of usage - counts...
----------------- ------------------ -----------------
Figure 1
Figure 1 illustrates the relationship between the selection criteria,
linkage and usage policies.
The PDP is not aware of the instance identifier of the usage feedback
policy when installing the selection criteria and feedback linkage
policies. The usage feedback policy is instantiated on the PEP by
the installation of a feedback report linkage and the PEP designates
the instance identifier. The usage feedback policy class always
contains an attribute of type ReferenceId that contains the instance
value of the associated frwkFeedbackLinkTable instance installed by
the PDP. An example of this is the attribute
frwkFeedbackTrafficLinkRef.
2.2. Normal Operations
2.2.1. Connection Establishment and Initial Configuration Request
The Accounting Timer object in the COPS Connection Accept message
contains the minimum number of seconds between reporting intervals as
described in [COPS] and [FEEDBACKFWK]. This is used as the basic
unit of measurement in defining intervals for specific usage policies
with the frwkFeedbackLinkInterval attribute.
The PEP notifies the PDP of the selection criteria policy classes and
usage policy classes it supports during the initial request for
configuration data using frwkPRCSupport instances [FR-PIB]. The PEP
also indicates whether it supports the frwkFeedbackLinkTable as well.
The PDP responds to the initial request for configuration with a
DECISION that installs policies. The PDP may also specify maximum
reporting intervals associated with each of the usage policies. This
is done with the frwkFeedbackLinkInterval attribute in the
frwkFeedbackLink class. It may also specify reporting thresholds by
including an instance of a threshold class (e.g.
frwkFeedbackTrafficThreshold) in the decision. The PEP monitors and
records the usage per the conditions defined by its associated
selection criteria policy. Periodically the PEP reports the usage
with a REPORT message or provides a REPORT when solicited by the PDP.
The PDP solicits usage feedback with the frwkFeedbackActionIndicator
attribute of the frwkFeedbackAction class.
2.2.2. Unsolicited Reports - Periodic Reporting
Reporting may be periodic in nature and unsolicited. The intervals
at which the unsolicited reports are provided by the PEP are defined
in the specific Linkage policies. The defined intervals are based on
the number of seconds specified by the PDP in the ACCT Timer value.
The PDP may specify that the associated usage instance be included in
a periodic unsolicited report only if the threshold is reached and/or
if the usage value has changed from the previous reporting interval.
There are cases when the PEP must supply unsolicited feedback reports
that may not fall on an interval boundary. The PEP MUST provide an
unsolicited REPORT containing all defined usage instances just prior
to the PEP issuing a Delete Request State and just prior to the PEP
de-activating a PIB instance context.
2.2.3. Unsolicited Reports - Reporting Conditions
Periodic unsolicited reports for individual usage feedback instances
can be suppressed by specifying additional conditions in the
frwkFeedbackLink instances. Supported conditions are:
ChangeOnly
If this flag is set in the frwkFeedbackLinkFlags attribute, the
associated usage instance is only included in a periodic
unsolicited report if its value changed since the last unsolicited
report.
Threshold
If this flag is set in the frwkFeedbackLinkFlags attribute, the
associated usage instance is only included in a periodic
unsolicited report if the threshold condition referenced in the
frwkLinkThreshold field evaluates successfully for the associated
usage instance.
Both conditions can be combined in one frwkFeedbackLinkUsage object.
In this case, both conditions need to succeed for the usage instance
to be reported.
Unsolicited reports triggered by a Delete Request State or the
deactivation of a PIB instance are not subject to these conditions -
all usage objects must be included in these cases.
2.2.4. Solicited Reports
The PDP may solicit policy usage feedback by issuing an unsolicited
Decision containing the frwkFeedbackActionIndicator set to
`solicitReport'. The PEP is to provide a solicited REPORT feedback
containing usage feedback. The PEP shall continue to provide
periodic feedback at the specified intervals established at client
connection acceptance.
The reporting conditions (ChangeOnly and Threshold) do not affect
solicited reports - all requested usage instances must be included.
2.2.5. Resuming and Suspending Periodic Feedback Reporting
The PDP may suspend usage monitoring and tracking at the PEP with the
frwkFeedbackActionIndicator set to 'suspendMonitoringAndReports'.
The PEP must stop tracking usage information and must not issue any
feedback reports. The PDP may only suspend feedback reporting by
setting the ActionIndicator to 'suspendReports'. The PEP must cease
sending unsolicited reports but is to continue monitoring and
tracking usage. The PDP may resume the sending of feedback reports
and may resume usage monitoring by setting the ActionIndicator to
'resume'.
The PDP may suspend or resume all usage instances or the PDP may
specify one or more instances that are to be suspended or resumed.
The frwkFeedbackActionList attribute contains a tag identifier that
references a list of one or more frwkFeedbackActionList instances.
The PDP may halt usage monitoring, tracking and reporting of usage
policies by removing the associated Linkage entry.
2.2.6. Failover
In the event that the connection is lost between the PEP and PDP, the
PEP continues to track usage information as long as it continues to
operate with the installed policy. When the locally installed policy
at the PEP eXPires, the usage policy data also expires.
Upon successful reconnection where the PEP is still caching policy,
the PDP indicates to the PEP that the PEP may resume sending of the
COPS accounting type report messages. The PDP does this by issuing
an unsolicited decision containing the frwkFeedbackResumeIndicator
set to 'resume'. The PEP should resume reporting at the next
appropriate feedback interval established upon the acceptance of the
re-connection. The PDP is aware of the request state Handle(s) and
the supported PRCs either through the state synchronization mechanism
or because the PDP considers itself synchronized with the PEP upon
reconnection.
2.3. Usage Policy and Under-specified Selection Criteria
Some of the usage policy objects created in the PEP with COPS-PR can
be used by the PEP multiple times - they effectively act as templates
for the objects created by the PEP. COPS-PR only has the identity
(OID) of the object that is shared between all the assignments the
PEP created. However it is desirable to collect usage information
for each of the derived objects individually.
This capability is achieved in the feedback framework PIB by
distributing additional information to qualify a specific assignment
of an object between the selection criteria PRC and the feedback
usage PRC.
A selection criteria PRC that refers to a shared object, but contains
no qualifying information, selects all of the object's assignments.
Such a selection criteria PRC SHOULD be combined with a feedback
usage PRC that includes all the necessary information to identify a
specific assignment - a single selection criteria policy can then
result in the generation of many feedback usage objects, one for each
derived object.
If the selection criteria PRC contains all the required qualifying
attributes for a specific assignment, it is combined with a feedback
usage PRC that only contains the desired metrics but no additional
attributes.
Example:
A frwkRoleCombo instance may be used as a selection criteria,
identifying a set of interfaces through their role combination and
capability set. If it is desired to get per-interface traffic
statistics, the usage PRC has to include an additional attribute
to qualify the specific interface.
This could be achieved by linking the frwkFeedbackIfTraffic class
with a frwkRoleCombo instance in a frwkFeedbackLink instance.
Multiple frwkFeedbackIfTraffic instances will be created by the
PEP, one for each interface selected by the frwkRoleCombo
instance. The frwkFeedbackIfTraffic class contains the
frwkFeedbackIfTrafficIfIndex attribute that allows the PDP to
identify each interface's individual counters when the PEP reports
the frwkFeedbackIfTraffic instances.
If traffic usage collection is only desired for an individual
interface, a selection criteria should be used that qualifies the
interface completely, for example a frwkIfRoleCombo instance. In
this case, it can be linked to the usage class that has no
additional qualifying attributes, frwkFeedbackTraffic.
3. Summary of the Feedback Framework Policy Information Base
3.1. SPPI ACCESS Clause Report-Only
The selection criteria and linkage policy classes follow the
definitions specified by [SPPI]. This structure specifies well-
defined policy classes and their instances residing in a common,
virtual repository [FR-PIB]. The additional PIB-ACCESS clause
attribute of "report-only" denotes the usage policy class reported by
the PEP.
3.2. Usage32 and Usage64 Textual Conventions
The SPPI does not support the Counter32/64 textual conventions (TC)
of SNMP - for feedback collection two similar textual conventions
have been defined in this PIB: Usage32 and Usage64.
In addition to the differential functionality of 'Counter', where
only the difference between two samples generally carries
information, a single value of a 'Usage' attribute usually provides
absolute information, since
- its initial value is known (0)
- no wrap-around events should occur
- the time or event when the initial value was set should be
available directly or indirectly from other objects.
When 'Usage' attributes are defined in a PRC, events that could cause
a reset of the attribute to its initial value should be defined in
the description as well as the mechanism that allows the PDP to
detect the time of the last reset.
No usual COPS activity however should cause the reset of a Usage
attribute. In the case of a suspension of monitoring activity
(frwkFeedbackActionIndicator set to 'suspendMonitoringAndReports'),
'Usage' attributes should keep their values and continue counting
after monitoring is resumed.
3.3. Feedback Groups and PRCs
These policy classes defined in this PIB are common to account type
reporting for various technologies and apply to ALL SUBJECT-
CATEGORIES. The policy classes are divided into three new groups,
namely, The Feedback Report Group, The Feedback Usage Group and The
Feedback Selection Group.
The policy classes in the Feedback Report Group are:
- Feedback Action
- Feedback Action List
- Feedback Selection Usage Combination Capability
- Feedback Linkage
- Feedback Traffic Statistics Threshold
The policy classes in the Feedback Usage Group are:
- Feedback Traffic
- Feedback Interface Traffic
The policy class in the Feedback Selection Group is:
- Feedback RoleCombo Filter Selection
3.3.1. Feedback Action
The Feedback Action class contains the attributes that specify action
that the PEP is to take regarding policy usage, monitoring and
tracking. The PDP may suspend usage monitoring and periodic
reporting, suspend periodic reporting only, resume usage and periodic
reporting or solicit immediate reporting. The action may affect all
feedback policies or be associated with one or more frwkFeedbackLink
instances.
The frwkFeedbackActionIndicator attribute defines the action. The
frwkFeedbackActionPri attribute indicates whether the action applies
to all of the usage policies or to a list. The
frwkFeedbackActionList attribute is the identifier of the list of
Linkage policy instances to which the action is to be applied.
The PDP can solicit the PEP for immediate usage feedback. The PEP
shall respond with a solicited report containing the usage feedback.
The PDP can direct the resumption of usage monitoring and reporting
per the defined intervals. For example, the PEP may have re-
connected to a PDP and has cached usage policies. The PDP indicates
to the PEP to resume usage tracking and monitoring and to send all
the cached usage policy. The PEP shall respond at the next
appropriate interval with an unsolicited report containing the usage
feedback.
The PDP can suspend the monitoring of usage policy. The PEP
maintains the current usage that has been monitored, but discontinues
any further monitoring until the PDP directs the PEP to resume
monitoring in a subsequent Decision.
The PDP can also suspend just the reporting of usage, but not
interrupt the monitoring and tracking of usage. The PEP shall
discontinue sending Report messages with usage feedback until the PDP
directs the PEP to resume. The PEP then begins reporting the usage
feedback at the next interval.
3.3.2. Feedback Action List
This class defines sets of linkage instances that can be referred to
from the frwkFeedbackActionList attribute.
3.3.3. Feedback Linkage Capability
This class defines the valid selection criteria PRC, usage PRC and
threshold PRC combinations supported by the PEP.
3.3.4. Feedback Linkage
This class links the selection criteria instance with the usage
class. This table permits the reuse of a selection criteria instance
for multiple usage policies.
The linkage table also permits the definition of a maximum reporting
interval to use when issuing the COPS accounting type reports for the
usage instance. A value of 0 in this attribute indicates that the
usage policy must be solicited.
3.3.5. Feedback Traffic Statistics Threshold
This class is used to provide threshold values for the attributes
described in the traffic usage classes below.
3.3.6. Feedback Traffic
This class includes the packet counts, byte counts and a reference to
the associated Linkage instance.
3.3.7. Feedback Interface Traffic
This class is similar to the previous Feedback Traffic class, except
that it includes an additional reference to an interface index. This
class should be used with a selection criteria instance that matches
an element that is assigned to multiple interfaces. The interface
field can be used to associate the instances of this table with the
specific element's assignment.
3.3.8. Feedback RoleCombo Filter Selection
This class is used as selection criteria based on role combination,
capability set and a filter instance.
4. The Feedback Framework PIB Module
FRAMEWORK-FEEDBACK-PIB PIB-DEFINITIONS ::= BEGIN
IMPORTS
pib, Unsigned32, Unsigned64, Integer32,
MODULE-IDENTITY, OBJECT-TYPE, MODULE-COMPLIANCE, OBJECT-GROUP
FROM COPS-PR-SPPI
TruthValue, TEXTUAL-CONVENTION
FROM SNMPv2-TC
InstanceId, ReferenceId, Prid,
TagId, TagReferenceId
FROM COPS-PR-SPPI-TC
PrcIdentifierOid, PrcIdentifierOidOrZero
FROM FRAMEWORK-TC-PIB
frwkRoleComboEntry
FROM FRAMEWORK-PIB
InterfaceIndex
FROM IF-MIB;
frwkFeedbackPib MODULE-IDENTITY
SUBJECT-CATEGORIES { all }
LAST-UPDATED "200307140000Z" -- 14 July 2003
ORGANIZATION "IETF RAP WG"
CONTACT-INFO "IETF RAP WG
Email: rap@ops.ietf.org
Diana Rawlins
MCI
400 International Parkway
Richardson, Texas 75081
Phone: 972-729-4071
Email: Diana.Rawlins@mci.com
Amol Kulkarni
JF3-206
2111 NE 25th Ave
Hillsboro, Oregon 97124
Phone: 503-712-1168
Email: amol.kulkarni@intel.com
Kwok Ho Chan
Nortel Networks
600 Technology Park Drive
Billerica, MA 01821 USA
Phone: 978-288-8175
Email: khchan@nortelnetworks.com
Martin Bokaemper
Juniper Networks
700 Silver Seven Road
Kanata, ON, K2V 1C3, Canada
Phone: 613-591-2735
Email: mbokaemper@juniper.net
Dinesh G Dutt
Cisco Systems, Inc.
170 Tasman Dr.
San Jose, CA 95134-1706
Phone: 408-527-0955
Email: ddutt@cisco.com"
DESCRIPTION
"The PIB module containing the base set of policy rule
classes that are required for support of all policy
usage monitoring, tracking and reporting policies.
Copyright (C) The Internet Society (2003). This version
of this PIB module is part of RFC3571 see the RFC
itself for full legal notices."
REVISION "200307140000Z"
DESCRIPTION
"Initial version, published in RFC3571."
::= { pib 5 }
--
-- Textual Conventions
--
Usage32 ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Usage32 type represents a non-negative integer
which monotonically increases.
Usage32 initial value is 0 and the object-type using
Usage32 needs to specify when it is initialized.
The Usage32 type is intended to reflect the absolute
number of counted events, so that even a new PDP
after a COPS reconnect can use the value directly.
If there is the possibility that the maximum Usage32
value of 2^32-1 is exceeded during the lifetime
of the Usage32 object, the larger Usage64 type
should be used.
If conditions other than the reset of the COPS
subsystem exist that disrupt the monotonic
characteristics of Usage32, these conditions and a
method how to detect their presence should be
specified in the description of the object-type using
Usage32 or its enclosing object-types (e.g. the
Entry or Table object-type of the Usage32
object-type).
Whenever the monotonic increase of Usage32 is violated,
it should be reset to 0 and the fact that this occurred
should be indicated through an appropriate mechanism,
for example a corresponding object of type TimeStamp
or TimeAndDate."
SYNTAX Unsigned32
Usage64 ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The Usage64 type represents a non-negative integer
which monotonically increases.
Usage64 initial value is 0 and the object-type using
Usage64 needs to specify when it is initialized.
The Usage64 type is intended to reflect the absolute
number of counted events, so that even a new PDP
after a COPS reconnect can use the value directly.
The lifetime of the Usage64 object should be defined
in a way that ensures the maximum Usage64 value of
2^64-1 is never exceeded.
If conditions other than the reset of the COPS
subsystem exist that disrupt the monotonic
characteristics of Usage64, these conditions and a
method how to detect their presence should be
specified in the description of the object-type using
Usage64 or its enclosing object-types (e.g. the
Entry or Table object-type of the Usage64
object-type).
Whenever the monotonic increase of Usage64 is violated,
it should be reset to 0 and the fact that this occurred
should be indicated through an appropriate mechanism,
for example a corresponding object of type TimeStamp
or TimeAndDate."
SYNTAX Unsigned64
--
-- The feedback report group
--
frwkFeedbackGroupClasses
OBJECT IDENTIFIER ::= { frwkFeedbackPib 1 }
--
-- Feedback Action Table
--
frwkFeedbackActionTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrwkFeedbackActionEntry
PIB-ACCESS install
STATUS current
DESCRIPTION
"This class represents commands that the PDP sends to
suspend, resume or solicit collection or reporting of
usage data."
::= { frwkFeedbackGroupClasses 1}
frwkFeedbackActionEntry OBJECT-TYPE
SYNTAX FrwkFeedbackActionEntry
STATUS current
DESCRIPTION
"Each frwkFeedbackActionEntry represents a command from
the PDP. FrwkFeedbackActionIndicator specifies the
command itself while frwkFeedbackActionSpecificPri
indicates if all frwkFeedbackLink objects in the system
are affected by the command, or just the set that is
referenced by frwkFeedbackActionList."
PIB-INDEX { frwkFeedbackActionId}
::= { frwkFeedbackActionTable 1}
FrwkFeedbackActionEntry ::= SEQUENCE {
frwkFeedbackActionId InstanceId,
frwkFeedbackActionIndicator INTEGER,
frwkFeedbackActionSpecificPri TruthValue,
frwkFeedbackActionList TagReferenceId
}
frwkFeedbackActionId OBJECT-TYPE
SYNTAX InstanceId
STATUS current
DESCRIPTION
"An arbitrary integer index that uniquely identifies an
instance of the frwkFeedbackAction class."
::= { frwkFeedbackActionEntry 1}
frwkFeedbackActionIndicator OBJECT-TYPE
SYNTAX INTEGER {
suspendMonitoringAndReports(1),
suspendReports(2),
resume(3),
solicitReport(4)
}
STATUS current
DESCRIPTION
"The value indicates if the PEP is to send cached
usage policies via COPS accounting type report
messages.
The enumeration values are:
(1) suspendMonitoringAndReports
(2) suspendReports
(3) resume
(4) solicitReport "
::= { frwkFeedbackActionEntry 2 }
frwkFeedbackActionSpecificPri OBJECT-TYPE
SYNTAX TruthValue
STATUS current
DESCRIPTION
"A value of 0 indicates that the
frwkFeedbackActionList attribute should be ignored,
and the action applied to all policies. A value of
1 indicates that the action entry has a specific
list of policies to which it is to be applied."
::= { frwkFeedbackActionEntry 3}
frwkFeedbackActionList OBJECT-TYPE
SYNTAX TagReferenceId
PIB-TAG { frwkFeedbackActionListTag }
STATUS current
DESCRIPTION
"Identifies a group of frwkFeedbackLink instances
that this action should affect. The group is
identified through a tag reference in the
frwkFeedbackList class."
::= { frwkFeedbackActionEntry 4}
--
-- Feedback Action List Table
--
frwkFeedbackActionListTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrwkFeedbackActionListEntry
PIB-ACCESS install
STATUS current
DESCRIPTION
"This class defines groups of linkage instances.
Groups can be referenced by commands sent by the
PDP in a frwkFeedbackActionEntry -in this case the
command affects all linkage instances that are part
of the group.
A group can be referred to by its tag stored in
frwkFeedbackActionListTag."
::= { frwkFeedbackGroupClasses 2}
frwkFeedbackActionListEntry OBJECT-TYPE
SYNTAX FrwkFeedbackActionListEntry
STATUS current
DESCRIPTION
"Each instance associates a linkage instance with a
specific ActionListGroup."
PIB-INDEX {frwkFeedbackActionListId }
UNIQUENESS { frwkFeedbackActionListTag,
frwkFeedbackActionListRefID
}
::= { frwkFeedbackActionListTable 1}
FrwkFeedbackActionListEntry::= SEQUENCE {
frwkFeedbackActionListId InstanceId,
frwkFeedbackActionListTag TagId,
frwkFeedbackActionListRefID ReferenceId
}
frwkFeedbackActionListId OBJECT-TYPE
SYNTAX InstanceId
STATUS current
DESCRIPTION
"Arbitrary integer index that uniquely
identifies an instance of the class."
::= { frwkFeedbackActionListEntry 1 }
frwkFeedbackActionListTag OBJECT-TYPE
SYNTAX TagId
STATUS current
DESCRIPTION
"Identifies a group of linkage instances that can
be referenced from the Action class."
::= { frwkFeedbackActionListEntry 2 }
frwkFeedbackActionListRefID OBJECT-TYPE
SYNTAX ReferenceId
PIB-REFERENCES { frwkFeedbackLinkEntry }
STATUS current
DESCRIPTION
"A frwkFeedbackLink instance that is referred to
by this ReferenceId becomes part of the group,
that is identified by the
frwkFeedbackActionListTag."
::= { frwkFeedbackActionListEntry 3 }
--
-- The Feedback Link Capability Table
--
frwkFeedbackLinkCapsTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrwkFeedbackLinkCapsEntry
PIB-ACCESS notify
STATUS current
DESCRIPTION
"Instances of the frwkFeedbackLink class reference
instances of selection and threshold classes and a
usage class.
This class allows the PEP to communicate valid
combinations of these three classes to the PDP."
::= { frwkFeedbackGroupClasses 3}
frwkFeedbackLinkCapsEntry OBJECT-TYPE
SYNTAX FrwkFeedbackLinkCapsEntry
STATUS current
DESCRIPTION
"The attributes of this class identify valid
combinations of selection criteria, usage and
threshold classes for feedback."
PIB-INDEX { frwkFeedbackLinkCapsId }
UNIQUENESS {
frwkFeedbackLinkCapsSelection,
frwkFeedbackLinkCapsUsage,
frwkFeedbackLinkCapsThreshold
}
::= {frwkFeedbackLinkCapsTable 1}
FrwkFeedbackLinkCapsEntry ::= SEQUENCE {
frwkFeedbackLinkCapsId InstanceId,
frwkFeedbackLinkCapsSelection PrcIdentifierOid,
frwkFeedbackLinkCapsUsage PrcIdentifierOid,
frwkFeedbackLinkCapsThreshold PrcIdentifierOidOrZero
}
frwkFeedbackLinkCapsId OBJECT-TYPE
SYNTAX InstanceId
STATUS current
DESCRIPTION
"An arbitrary integer index that uniquely identifies an
instance of the frwkFeedbackLinkCaps class."
::= { frwkFeedbackLinkCapsEntry 1}
frwkFeedbackLinkCapsSelection OBJECT-TYPE
SYNTAX PrcIdentifierOid
STATUS current
DESCRIPTION
"The identifier of a class that is supported by the
device for feedback selection in combination with the
usage and threshold classes referenced in this
instance."
::= { frwkFeedbackLinkCapsEntry 2}
frwkFeedbackLinkCapsUsage OBJECT-TYPE
SYNTAX PrcIdentifierOid
STATUS current
DESCRIPTION
"The identifier of the usage class that is supported by
the PEP in combination with the selection and threshold
classes referenced in this instance."
::= { frwkFeedbackLinkCapsEntry 3}
frwkFeedbackLinkCapsThreshold OBJECT-TYPE
SYNTAX PrcIdentifierOidOrZero
STATUS current
DESCRIPTION
"The identifier of the threshold class that is
supported by the PEP in combination with the selection
and usage classes referenced in this instance.
0.0 is used if this combination does not allow a
threshold."
::= { frwkFeedbackLinkCapsEntry 4}
--
-- The Feedback Report Linkage Table
--
frwkFeedbackLinkTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrwkFeedbackLinkEntry
PIB-ACCESS install
STATUS current
DESCRIPTION
"This class associates the selection criteria with the
usage policy. It also permits the defining of the max
interval used for reporting the usage instance."
::= { frwkFeedbackGroupClasses 4}
frwkFeedbackLinkEntry OBJECT-TYPE
SYNTAX FrwkFeedbackLinkEntry
STATUS current
DESCRIPTION
"This class associates the selection criteria with the
usage policy. It also permits the defining of the max
interval used for reporting the usage instance."
PIB-INDEX { frwkFeedbackLinkId }
UNIQUENESS {frwkFeedbackLinkSel,
frwkFeedbackLinkUsage }
::= {frwkFeedbackLinkTable 1}
FrwkFeedbackLinkEntry ::= SEQUENCE {
frwkFeedbackLinkId InstanceId,
frwkFeedbackLinkSel Prid,
frwkFeedbackLinkUsage PrcIdentifierOid,
frwkFeedbackLinkInterval Integer32,
frwkFeedbackLinkThreshold Prid,
frwkFeedbackLinkFlags BITS
}
frwkFeedbackLinkId OBJECT-TYPE
SYNTAX InstanceId
STATUS current
DESCRIPTION
"An arbitrary integer index that uniquely identifies an
instance of the frwkFeedbackLinkTable class."
::= { frwkFeedbackLinkEntry 1}
frwkFeedbackLinkSel OBJECT-TYPE
SYNTAX Prid
STATUS current
DESCRIPTION
"The PRID of the Policy Class instance as the monitoring
point, or the PRID of the selection criteria instance that
defines the conditions for monitoring, to be use by the
PEP for usage reporting."
::= { frwkFeedbackLinkEntry 2}
frwkFeedbackLinkUsage OBJECT-TYPE
SYNTAX PrcIdentifierOid
STATUS current
DESCRIPTION
"The identifier of the usage class that the PEP uses to
monitor, record and report."
::= { frwkFeedbackLinkEntry 3}
frwkFeedbackLinkInterval OBJECT-TYPE
SYNTAX Integer32
STATUS current
DESCRIPTION
"Maximum interval in units of the value of the
Accounting Timer specified by the PDP in the client
accept message. A frwkFeedbackLinkInterval of 1 is
equal to the value of the Accounting Timer. This value
must be 1 or greater. "
::= { frwkFeedbackLinkEntry 4}
frwkFeedbackLinkThreshold OBJECT-TYPE
SYNTAX Prid
STATUS current
DESCRIPTION
"The PRID of a threshold class instance. This instance
specifies the threshold values for the usage policy."
::= { frwkFeedbackLinkEntry 5}
frwkFeedbackLinkFlags OBJECT-TYPE
SYNTAX BITS {
periodic(0),
threshold(1),
changeOnly(2)
}
STATUS current
DESCRIPTION
"This value indicates the reporting basis of the usage
policy. The feed back may be generated on demand, on a
periodic basis regardless of a change in value from the
previous report, on a periodic basis if a change in
value has occurred, or the usage is reported when an
identified threshold value in the usage instance has
been reached.
If the 'periodic' flag is set, the PEP will provide
unsolicited reports at the rate specified in
frwkFeedbackLinkInterval.
If the 'periodic' flag is not set, reports will only be
generated when solicited by the PDP.
The 'threshold' and 'changeOnly' flags make the
periodic reports conditional - these flags only make
sense in combination with the 'periodic' flag."
::= { frwkFeedbackLinkEntry 6}
--
-- The Threshold class that accompanies the above Usage PRCs
--
frwkFeedbackTrafficThresTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrwkFeedbackTrafficThresEntry
PIB-ACCESS install
STATUS current
DESCRIPTION
"This class defines the threshold attributes
corresponding to usage attributes specified in
frwkFeedbackTrafficTable, frwkFeedbackIfTrafficTable
and other similar usage classes.
The usage object is considered to match the threshold
condition if at least one of the packet or byte
threshold conditions match.
The byte and packet thresholds are considered to
match, if the threshold is present (not ASN1 NULL)
and the corresponding usage value exceeds the
threshold."
::= { frwkFeedbackGroupClasses 5}
frwkFeedbackTrafficThresEntry OBJECT-TYPE
SYNTAX FrwkFeedbackTrafficThresEntry
STATUS current
DESCRIPTION
"Defines the attributes to hold threshold values."
PIB-INDEX {frwkFeedbackTrafficThresId}
::= {frwkFeedbackTrafficThresTable 1}
FrwkFeedbackTrafficThresEntry ::= SEQUENCE {
frwkFeedbackTrafficThresId InstanceId,
frwkFeedbackTrafficThresPackets Unsigned64,
frwkFeedbackTrafficThresBytes Unsigned64
}
frwkFeedbackTrafficThresId OBJECT-TYPE
SYNTAX InstanceId
STATUS current
DESCRIPTION
"Arbitrary integer index that uniquely identifies
an instance of the class."
::= { frwkFeedbackTrafficThresEntry 1 }
frwkFeedbackTrafficThresPackets OBJECT-TYPE
SYNTAX Unsigned64
STATUS current
DESCRIPTION
"The threshold, in terms of packets, that must be
matched or exceeded to trigger a report in the
next reporting interval."
::= { frwkFeedbackTrafficThresEntry 2 }
frwkFeedbackTrafficThresBytes OBJECT-TYPE
SYNTAX Unsigned64
STATUS current
DESCRIPTION
"The threshold, in terms of bytes, that must be
exceeded to trigger a report in the next reporting
interval."
::= { frwkFeedbackTrafficThresEntry 3 }
--
-- All actual usage classes are in the separate
-- frwkFeedbackUsageClasses group
--
frwkFeedbackUsageClasses
OBJECT IDENTIFIER ::= { frwkFeedbackPib 2 }
--
-- The generic traffic (byte & packet count) usage class
--
frwkFeedbackTrafficTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrwkFeedbackTrafficEntry
PIB-ACCESS report-only
STATUS current
DESCRIPTION
"This class defines the usage attributes that the PEP
is to monitor for plain traffic handling elements
like filters. All packets and the bytes contained in
these packets are counted. It also contains the PRID
of the linkage instance associating the selection
criteria instance with the usage instance."
::= { frwkFeedbackUsageClasses 1}
frwkFeedbackTrafficEntry OBJECT-TYPE
SYNTAX FrwkFeedbackTrafficEntry
STATUS current
DESCRIPTION
"Defines the attributes the PEP is to monitor,
record and report."
PIB-INDEX {frwkFeedbackTrafficId}
UNIQUENESS { frwkFeedbackTrafficLinkRefID }
::= {frwkFeedbackTrafficTable 1}
FrwkFeedbackTrafficEntry ::= SEQUENCE {
frwkFeedbackTrafficId InstanceId,
frwkFeedbackTrafficLinkRefID ReferenceId,
frwkFeedbackTrafficPacketCount Usage64,
frwkFeedbackTrafficByteCount Usage64
}
frwkFeedbackTrafficId OBJECT-TYPE
SYNTAX InstanceId
STATUS current
DESCRIPTION
"Arbitrary integer index that uniquely identifies
an instance of the class."
::= { frwkFeedbackTrafficEntry 1 }
frwkFeedbackTrafficLinkRefID OBJECT-TYPE
SYNTAX ReferenceId
PIB-REFERENCES { frwkFeedbackLinkEntry }
STATUS current
DESCRIPTION
"The ReferenceId of the Linkage policy instance used
to base this usage policy instance upon."
::= { frwkFeedbackTrafficEntry 2 }
frwkFeedbackTrafficPacketCount OBJECT-TYPE
SYNTAX Usage64
STATUS current
DESCRIPTION
"The count of packets handled by the associated
element. The initial value of 0 is set when the
frwkFeedbackTraffic instance is created, for example
triggered through the creation of a frwkFeedbackLink
instance."
::= {frwkFeedbackTrafficEntry 3}
frwkFeedbackTrafficByteCount OBJECT-TYPE
SYNTAX Usage64
STATUS current
DESCRIPTION
"The byte count of packets handled by the associated
element. The initial value of 0 is set when the
frwkFeedbackTraffic instance is created."
::= { frwkFeedbackTrafficEntry 4}
--
-- The traffic usage class, qualified for an interface
--
frwkFeedbackIfTrafficTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrwkFeedbackIfTrafficEntry
PIB-ACCESS report-only
STATUS current
DESCRIPTION
"A usage class similar to the basic Traffic class that
also contains a reference to an interface index. This
class should be used with an underspecified selection
criteria entry from the frwkRoleComboTable that matches
an element that can be assigned to multiple interface
indices. The interface field can be used to associate
the instances of this class with the specific element's
assignment."
::= { frwkFeedbackUsageClasses 2 }
frwkFeedbackIfTrafficEntry OBJECT-TYPE
SYNTAX FrwkFeedbackIfTrafficEntry
STATUS current
DESCRIPTION
"Defines the attributes the PEP is to monitor,
record and report."
PIB-INDEX {frwkFeedbackIfTrafficId}
UNIQUENESS { frwkFeedbackIfTrafficLinkRefID,
frwkFeedbackIfTrafficIfIndex }
::= {frwkFeedbackIfTrafficTable 1}
FrwkFeedbackIfTrafficEntry ::= SEQUENCE {
frwkFeedbackIfTrafficId InstanceId,
frwkFeedbackIfTrafficLinkRefID ReferenceId,
frwkFeedbackIfTrafficIfIndex InterfaceIndex,
frwkFeedbackIfTrafficPacketCount Usage64,
frwkFeedbackIfTrafficByteCount Usage64
}
frwkFeedbackIfTrafficId OBJECT-TYPE
SYNTAX InstanceId
STATUS current
DESCRIPTION
"Arbitrary integer index that uniquely identifies
an instance of the class."
::= { frwkFeedbackIfTrafficEntry 1 }
frwkFeedbackIfTrafficLinkRefID OBJECT-TYPE
SYNTAX ReferenceId
PIB-REFERENCES { frwkFeedbackLinkEntry }
STATUS current
DESCRIPTION
"The ReferenceId of the Linkage policy instance used
to base this usage policy instance upon."
::= { frwkFeedbackIfTrafficEntry 2 }
frwkFeedbackIfTrafficIfIndex OBJECT-TYPE
SYNTAX InterfaceIndex
STATUS current
DESCRIPTION
"The value of this attribute is the ifIndex which is
associated with the specified RoleCombination and
interface capability set name."
::= { frwkFeedbackIfTrafficEntry 3 }
frwkFeedbackIfTrafficPacketCount OBJECT-TYPE
SYNTAX Usage64
STATUS current
DESCRIPTION
"The count of packets handled by the associated
element. The initial value of 0 is set when the
frwkFeedbackIfTraffic instance is created."
::= { frwkFeedbackIfTrafficEntry 4 }
frwkFeedbackIfTrafficByteCount OBJECT-TYPE
SYNTAX Usage64
STATUS current
DESCRIPTION
"The byte count of packets handled by the associated
element. The initial value of 0 is set when the
frwkFeedbackIfTraffic instance is created."
::= { frwkFeedbackIfTrafficEntry 5 }
--
-- All Selection classes are in the separate
-- FrwkFeedbackSelectionClasses group
--
frwkFeedbackSelectionClasses
OBJECT IDENTIFIER ::= { frwkFeedbackPib 3 }
--
-- The Role Combination Filter Selection Table
--
frwkFeedbackRoleFilterSelTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrwkFeedbackRoleFilterSelEntry
PIB-ACCESS install
STATUS current
DESCRIPTION
"A selection class that defines selection of objects
for monitoring based on the role combination,
capability set and a filter."
::= { frwkFeedbackSelectionClasses 1 }
frwkFeedbackRoleFilterSelEntry OBJECT-TYPE
SYNTAX FrwkFeedbackRoleFilterSelEntry
STATUS current
DESCRIPTION
"Each instance selects a filter on multiple interfaces
that share the same frwkRoleCombo instance."
PIB-INDEX { frwkFeedbackRoleFilterSelId}
UNIQUENESS { frwkFeedbackRoleFilterSelRCombo,
frwkFeedbackRoleFilterSelFilter
}
::= {frwkFeedbackRoleFilterSelTable 1}
FrwkFeedbackRoleFilterSelEntry ::= SEQUENCE {
frwkFeedbackRoleFilterSelId InstanceId,
frwkFeedbackRoleFilterSelRCombo ReferenceId,
frwkFeedbackRoleFilterSelFilter Prid
}
frwkFeedbackRoleFilterSelId OBJECT-TYPE
SYNTAX InstanceId
STATUS current
DESCRIPTION
"Arbitrary integer index that uniquely identifies
an instance of the class."
::= { frwkFeedbackRoleFilterSelEntry 1 }
frwkFeedbackRoleFilterSelRCombo OBJECT-TYPE
SYNTAX ReferenceId
PIB-REFERENCES { frwkRoleComboEntry }
STATUS current
DESCRIPTION
"The ReferenceId of the frwkRoleComboTable policy
instance used for selection."
::= { frwkFeedbackRoleFilterSelEntry 2 }
frwkFeedbackRoleFilterSelFilter OBJECT-TYPE
SYNTAX Prid
STATUS current
DESCRIPTION
"The identifier of a filter instance. Valid classes
are the subclasses of frwkBaseFilter:
- frwkIpFilter
- frwk802Filter
- frwkILabelFilter"
::= { frwkFeedbackRoleFilterSelEntry 3 }
--
-- Compliance Section
--
frwkFeedbackPibConformance
OBJECT IDENTIFIER ::= { frwkFeedbackPib 4 }
frwkFeedbackPibCompliances
OBJECT IDENTIFIER ::= { frwkFeedbackPibConformance 1 }
frwkFeedbackPibGroups
OBJECT IDENTIFIER ::= { frwkFeedbackPibConformance 2 }
frwkFeedbackPibCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"Describes the requirements for conformance to the feedback
framework PIB"
MODULE -- this module
MANDATORY-GROUPS { frwkFeedbackLinkCapsGroup,
frwkFeedbackLinkGroup,
frwkFeedbackActionGroup }
GROUP frwkFeedbackActionListGroup
DESCRIPTION
"The frwkFeedbackActionListGroup is mandatory if
actions on subsets linkEntries are to be
supported."
GROUP frwkFeedbackTrafficGroup
DESCRIPTION
"The frwkFeedbackTrafficGroup is mandatory if
monitoring of traffic data is to be supported."
GROUP frwkFeedbackTrafficThresGroup
DESCRIPTION
"The frwkFeedbackTrafficThresGroup is mandatory
if conditional reporting of traffic usage
thresholds is to be supported."
GROUP frwkFeedbackIfTrafficGroup
DESCRIPTION
"The frwkFeedbackIfTrafficGroup is mandatory if
per-interface usage collection of traffic data is
to be supported."
GROUP frwkFeedbackRoleFilterSelGroup
DESCRIPTION
"The frwkFeedbackRoleFilterSelGroup is mandatory
if monitoring of filters referenced through the
frwkRoleCombo class is to be supported."
::= { frwkFeedbackPibCompliances 1 }
frwkFeedbackLinkCapsGroup OBJECT-GROUP
OBJECTS {
frwkFeedbackLinkCapsId,
frwkFeedbackLinkCapsSelection,
frwkFeedbackLinkCapsUsage,
frwkFeedbackLinkCapsThreshold }
STATUS current
DESCRIPTION
"Objects from the frwkFeedbackLinkCapsTable."
::= { frwkFeedbackPibGroups 1 }
frwkFeedbackLinkGroup OBJECT-GROUP
OBJECTS {
frwkFeedbackLinkId,
frwkFeedbackLinkSel,
frwkFeedbackLinkUsage,
frwkFeedbackLinkInterval,
frwkFeedbackLinkThreshold,
frwkFeedbackLinkFlags }
STATUS current
DESCRIPTION
"Objects from the frwkFeedbackLinkTable."
::= { frwkFeedbackPibGroups 2 }
frwkFeedbackActionGroup OBJECT-GROUP
OBJECTS {
frwkFeedbackActionId,
frwkFeedbackActionIndicator,
frwkFeedbackActionSpecificPri,
frwkFeedbackActionList }
STATUS current
DESCRIPTION
"Objects from the frwkFeedbackActionTable."
::= { frwkFeedbackPibGroups 3 }
frwkFeedbackActionListGroup OBJECT-GROUP
OBJECTS {
frwkFeedbackActionListId,
frwkFeedbackActionListTag,
frwkFeedbackActionListRefID }
STATUS current
DESCRIPTION
"Objects from the frwkFeedbackActionListTable."
::= { frwkFeedbackPibGroups 4 }
frwkFeedbackTrafficGroup OBJECT-GROUP
OBJECTS {
frwkFeedbackTrafficId,
frwkFeedbackTrafficLinkRefID,
frwkFeedbackTrafficPacketCount,
frwkFeedbackTrafficByteCount }
STATUS current
DESCRIPTION
"Objects from the frwkFeedbackTrafficTable."
::= { frwkFeedbackPibGroups 5 }
frwkFeedbackTrafficThresGroup OBJECT-GROUP
OBJECTS {
frwkFeedbackTrafficThresId,
frwkFeedbackTrafficThresPackets,
frwkFeedbackTrafficThresBytes }
STATUS current
DESCRIPTION
"Objects from the frwkFeedbackTrafficThresTable."
::= { frwkFeedbackPibGroups 6 }
frwkFeedbackIfTrafficGroup OBJECT-GROUP
OBJECTS {
frwkFeedbackIfTrafficId,
frwkFeedbackIfTrafficLinkRefID,
frwkFeedbackIfTrafficIfIndex,
frwkFeedbackIfTrafficPacketCount,
frwkFeedbackIfTrafficByteCount }
STATUS current
DESCRIPTION
"Objects from the frwkFeedbackIfTrafficTable."
::= { frwkFeedbackPibGroups 7 }
frwkFeedbackRoleFilterSelGroup OBJECT-GROUP
OBJECTS {
frwkFeedbackRoleFilterSelId,
frwkFeedbackRoleFilterSelRCombo,
frwkFeedbackRoleFilterSelFilter }
STATUS current
DESCRIPTION
"Objects from the frwkFeedbackRoleFilterSelTable."
::= { frwkFeedbackPibGroups 8 }
END
5. Security Considerations
This PIB defines structured information that may be sensitive when
transported by the COPS protocol [COPS-PR].
This PIB does not contain classes that directly contain security
relevant information like passwords or monetary amounts. However,
unauthorized access or changes to information defined in this PIB
could compromise network operations or reveal sensitive business or
personal information.
Specifically for the classes:
frwkFeedbackLinkCaps
This class has the ACCESS clause 'notify'. Access to this
information reveals feedback collection capabilities of the COPS
client and malicious changes could affect feedback operation by
misleading the server to generate corrupt feedback configuration.
frwkFeedbackLinkTable, frwkFeedbackAction, frwkFeedbackActionList,
frwkFeedbackTrafficThres, frwkFeedbackRoleFilterSel
These classes have the ACCESS clause 'install' and allow the COPS
server to control feedback collection and reporting on the client.
Access to this information exposes the client's configuration;
malicious changes could disrupt network or business operations and
raise privacy issues.
frwkFeedbackTraffic, frwkFeedbackIfTraffic
These classes have the ACCESS clause 'report-only' and contain the
usage information delivered from the COPS client to the server.
Unauthorized access to this information may reveal detailed
information on the network and its users. Malicious changes may
affect network and business operations.
[COPS] and [COPS-PR] define mechanisms to secure the COPS protocol
communication and implementations of COPS servers or clients
supporting this PIB MUST follow the security guidelines specified
there.
6. IANA Considerations
This document describes the frwkFeedbackPib Policy Information Base
(PIB) module for registration under the "pib" branch registered with
IANA. The IANA has assigned PIB number 5.
This PIB uses "all" in the SUBJECT-CATEGORY clause, so it applies to
all COPS client types. No new COPS client type is requested for this
PIB.
7. Acknowledgements
The authors would like to thank Dave Durham, Ravi Sahita, and Russell
Fenger of Intel and John K. Gallant of WorldCom for their
contribution to this document.
8. References
8.1. Normative References
[COPS] Durham, D., Boyle, J., Cohen, R., Herzog, S., Rajan,
R. and A. Sastry, "The COPS (Common Open Policy
Service) Protocol", RFC2748, January 2000.
[COPS-PR] Chan, K., Seligson, J., Durham, D., Gai, S.,
McCloghrie, K., Herzog, S., Reichmeyer, F., Yavatkar,
R. and A. Smith, "COPS Usage for Policy
Provisioning", RFC3084, May 2001.
[IFMIB] McCloghrie, K. and F. Kastenholz, "The Interfaces
Group MIB", RFC2863, June 2000.
[FR-PIB] Sahita, R., Hahn, S., Chan, K. and K. McCloghrie,
"Framework Policy Information Base", RFC3318, March
2003.
[FEEDBACKFWK] Rawlins, D., Kulkarni, A., Bokaemper, M. and K. Chan,
"Framework for Policy Usage Feedback for Common Open
Policy Service with Policy Provisioning (COPS-PR)",
RFC3483, March 2003.
[RFC2119] Bradner, S., "Key words for use in RFCs to Indicate
Requirement Levels", BCP 14, RFC2119, March 1997.
[RFC2578] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case,
J., Rose, M. and S. Waldbusser, "Structure of
Management Information Version 2 (SMIv2)", STD 58,
RFC2578, April 1999.
[RFC2579] McCloghrie, K., Perkins, D., Schoenwaelder, J., Case,
J., Rose, M. and S. Waldbusser, "Textual Conventions
for SMIv2", STD 58, RFC2579, April 1999.
8.2. Informational References
[COPS-TLS], Walker, J., Kulkarni, A.,"COPS Over TLS", Work in
Progress.
[DIFFSERV-PIB] Chan, K., Sahita, R., Hahn, S. and K. McCloghrie,
"Differentiated Services Quality of Service Policy
Information Base", RFC3317, March 2003.
9. Authors' Addresses
Diana Rawlins
MCI
400 International Parkway
Richardson, Texas 75081
Phone: 972-729-4071
EMail: Diana.Rawlins@mci.com
Amol Kulkarni
JF3-206
2111 NE 25th Ave
Hillsboro, Oregon 97124
Phone: 503-712-1168
EMail: amol.kulkarni@intel.com
Kwok Ho Chan
Nortel Networks
600 Technology Park Drive
Billerica, MA 01821 USA
Phone: 978-288-8175
EMail: khchan@nortelnetworks.com
Martin Bokaemper
Juniper Networks
700 Silver Seven Road
Kanata, ON, K2V 1C3, Canada
Phone: 613-591-2735
EMail: mbokaemper@juniper.net
Dinesh G Dutt
Cisco Systems, Inc.
170 Tasman Dr.
San Jose, CA 95134-1706
Phone: 408-527-0955
EMail: ddutt@cisco.com
10. Full Copyright Statement
Copyright (C) The Internet Society (2003). All Rights Reserved.
This document and translations of it may be copied and furnished to
others, and derivative works that comment on or otherwise explain it
or assist in its implementation may be prepared, copied, published
and distributed, in whole or in part, without restriction of any
kind, provided that the above copyright notice and this paragraph are
included on all such copies and derivative works. However, this
document itself may not be modified in any way, such as by removing
the copyright notice or references to the Internet Society or other
Internet organizations, except as needed for the purpose of
developing Internet standards in which case the procedures for
copyrights defined in the Internet Standards process must be
followed, or as required to translate it into languages other than
English.
The limited permissions granted above are perpetual and will not be
revoked by the Internet Society or its successors or assignees.
This document and the information contained herein is provided on an
"AS IS" basis and THE INTERNET SOCIETY AND THE INTERNET ENGINEERING
TASK FORCE DISCLAIMS ALL WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO ANY WARRANTY THAT THE USE OF THE INFORMATION
HEREIN WILL NOT INFRINGE ANY RIGHTS OR ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Acknowledgement
Funding for the RFCEditor function is currently provided by the
Internet Society.